Standard Models ICS/FB-A 9.5 10 15 20 25 30 Models ICX/FB-F 9.5 10 15 20 30 Unit Size: BHP 9.5 10 15 20 25 30 A. Boiler Height IN 67.5 63.5 69 72.5 74.5 82 MM 1715 1613 1753 1842 1892 2083 B. Boiler Height With Trim* IN 85 80.5 93 97 97 106.5 & Fuel
Read MoreWall-mounted, gas-fired condensing boiler For operation with natural gas and liquid propane gas Heating input 12 to 530 MBH 3.5 to 150 kW Read and save these instructions for future reference. Product may not be exactly as shown IMPORTANT H Do not
Read More1.4.3 Emissions3-4 The emissions from natural gas-fired boilers and furnaces include nitrogen oxides (NOx), carbon monoxide (CO), and carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), volatile organic compounds (VOCs), trace amounts of sulfur
Read MoreOf course, this never happens, therefore burner combustion air fans may be sized for 25% excess air, in which case the fan would deliver 12.5 ft 3 of air per 1 ft 3 of natural gas. Additionally, many burner manufacturers will size the combustion air fans to provide sufficient air to operate properly up to 2,000 feet in altitude, in which case the sea level capacity will be increased by an
Read More1010 Btuh for Natural Gas (See page 19, if local higher heating value exceeds these numbers). See page 19, for burner input adjustment. LEFT END VIEW FRONT VIEW RIGHT END VIEW Figure 1. Views - Dimensions - Data Figure 2. Base Assembly 2
Read MoreGas pressure regulator (PRV) - the purpose is to maintain the pilot fuel at a constant pressure as recommended by the burner manufacturer. Safety shut-off valve (SSOV) - automatically opens and shuts off fuel supply to the pilot burner. Testing of the fuel firing apparatus, including the flame safeguard system, is relatively easy.
Read MoreWall-mounted, gas-fired condensing boiler For operation with natural gas and liquid propane gas Heating input 12 to 530 MBH 3.5 to 150 kW Read and save these instructions for future reference. Product may not be exactly as shown IMPORTANT H Do not
Read MoreØ Check all burner control panel lights are "Ready". If not, check and rectify the faulty condition. Safety devices are worthless if they are not kept in operating condition and checked regularly. The fuel safety shut-off valves are no exception. To test the tightness of the
Read MoreØ Check all burner control panel lights are "Ready". If not, check and rectify the faulty condition. Safety devices are worthless if they are not kept in operating condition and checked regularly. The fuel safety shut-off valves are no exception. To test the tightness of the
Read MoreFireye provides a variety of burner control flame safeguard and combustion controls to the HVAC marketplace. BurnerPRO TM, BurnerLogix TM, Flame-Monitor TM and MicroM families provide safe and reliable light off of packaged burners used on commercial and industrial boilers as well as direct fired makeup air units and commercial hot water heaters.
Read More1.4.3 Emissions3-4 The emissions from natural gas-fired boilers and furnaces include nitrogen oxides (NOx), carbon monoxide (CO), and carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), volatile organic compounds (VOCs), trace amounts of sulfur
Read MoreNatural gas and combustion equipment safety continues to be considered a black art by many. Most sites have personnel that are not adequately trained in either the safe start-up/shutdown of equipment, daily operations, or proper testing and maintenance.